Specifications
Main Item |
Unit |
ZDC-100TPS |
|||
|---|---|---|---|---|---|
Locking Unit |
Locking force |
ton |
100 |
||
Die platen dimension |
mm |
580 x 580 |
|||
Tie bar distance |
mm |
382 x 382 |
|||
Die height distance |
mm |
120 ~ 420 |
|||
Die stroke |
mm |
240 |
|||
Tie bar diameter |
mm |
Ø70 |
|||
Die adjustment speed |
mm/min |
159(50HZ), 192(60HZ) |
|||
Ejecting unit |
Ejecting force |
ton |
6.6 |
||
Ejecting stroke |
mm |
70 |
|||
Core unit |
Electromagnetic valve |
PT |
1/2" x 1(set) |
||
Oil outlet |
PT |
1/2" x 2 (sets) |
|||
Electric system |
Motor capacity voltage |
KW |
Pump 7.5 Die adjustment 0.375 |
||
Power source |
V |
AC 200/220(50/60HZ) |
|||
Capacity of power source |
KVA |
12 |
|||
Shot unit |
Shot force |
ton |
13.3 |
||
Max. shot speed(*) |
M/Sec |
5.0 |
|||
Plunger stroke |
mm |
325 |
|||
Plunger tip penetration |
mm |
135 |
|||
Plunger tip diameter |
mm |
Min Ø 40 |
Med Ø 45 |
Max Ø 50 |
|
Shot pressure |
Kgf/cm2 |
1058 |
836 |
677 |
|
Casting area |
cm2 |
95 |
120 |
148 |
|
Net shot weight |
Kgf |
0.64 |
0.81 |
1.0 |
|
Cooling water system |
Cooling water inlet pipe diameter |
PT |
1" |
||
Die cooling water outlet pipe diameter (in & out) |
PT |
1" x 1 (inlet), 2" x 1 (outlet) |
|||
Number of die cooling water adjusting valve cooling water |
PC |
7 (inlet), 8 (outlet) |
|||
Die cooling water |
Ltr/min |
15~30 |
|||
Hydraulic system |
Die & ejecting pressure |
Kgf/cm2 |
100;100 |
||
Max. Intensified pressure of injection |
Kgf/cm2 |
210 |
|||
Cycling oil volume |
Ltr |
240 |
|||
Cooling water |
Ltr/min |
30 (Water temp 25oC) |
|||
Machine relation |
Machine size (LxWxH) |
mm |
4250x1400x1550 |
||
Machine weight |
ton |
3.3 |
Elevation & Platen Layout